Meter box hockey sticks are designed to suit internal or external cable entry into the meter box. The hockey sticks satisfy all NHBC requirements and are manufactured to BS EN ISO 9001-2015. Compliant with all relevant British Standards and all relevant Building Regulations. The internal cavity hockey stick is black and the surface mounted hockey stick is off-white in colour.
Timloc IW50BU Invisiweep Buff:The almost-invisible, multi-function wall weep for discharging water from external walls. Suited for use with the Timloc cavity tray system, over external lintels and on external masonry walls. Invisiweep has numerous patent-pending innovative features, including a venturi effect outlet tube that reduces water pressure, allowing for optimal drainage.
Timloc IW50BU Invisiweep Clear:The almost-invisible, multi-function wall weep for discharging water from external walls. Suited for use with the Timloc cavity tray system, over external lintels and on external masonry walls. Invisiweep has numerous patent-pending innovative features, including a venturi effect outlet tube that reduces water pressure, allowing for optimal drainage. Invisiweep satisfies all NHBC requirements and meets British standards: BS5250, BS5628 and BS8215. The 500mm Invisiweep extension provides the ideal solution for render and wide walls and can be easily cut to size on site.
Timloc IW50BU Invisiweep Terracotta:The almost-invisible, multi-function wall weep for discharging water from external walls. Suited for use with the Timloc cavity tray system, over external lintels and on external masonry walls. Invisiweep has numerous patent-pending innovative features, including a venturi effect outlet tube that reduces water pressure, allowing for optimal drainage. Invisiweep satisfies all NHBC requirements and meets British standards: BS5250, BS5628 and BS8215. The 500mm Invisiweep extension provides the ideal solution for render and wide walls and can be easily cut to size on site.
Efficient and durable primary roof ventilator supplied in convenient 1m lengths. An over fascia vent is used when the fascia board is fitted in the ends of the rafters, creating a situation where ventilation can only be positioned over the top of the board.
OF1 provides ventilation equivalent to a continuous 10mm opening (10,000mm²) and is used to ventilate pitched roofs of >15° and the roof void is uninhabited loft or attic space.
Uses: • For roof eaves ventilation • For flat roof abutment ventilation • On roofs where the eaves incorporate a fascia board • On roofs which do not incorporate a soffit board, or where an unbroken soffit board is required